800G Optical Transceivers

800G OSFP 2×DR4 Optical Transceiver | 500m SMF

800G OSFP 2×DR4 optical transceiver for links up to 500m over OS2 single-mode fiber. Dual MPO-12/APC, 1310nm PAM4, CMIS and DDM support.

Product Model GK-OSFP-800G-2DR4
Supply Manufacturer Direct
Service Compatibility & OEM Support

Send the equipment model, required quantity and link or installation conditions for a faster review.

800G OSFP 2×DR4 Optical Transceiver | 500m SMF
Product image shown for configuration reference. View full-size image
01 Configuration Review

Product specifications are checked against the actual equipment and link requirements.

02 Sample Validation

Samples can be supplied for platform, link and application validation before volume orders.

03 OEM Service

Compatible coding, customer labels, part numbers and packaging are available.

04 Batch Traceability

Production identification and test records support repeatable project supply.

Specifications, compatibility and ordering information

800G OSFP 2×DR4 Optical Transceiver

The GK-OSFP-800G-2DR4 is an 800Gb/s pluggable optical module developed for short-reach, high-capacity connections in AI computing clusters, cloud data centers and high-performance Ethernet networks.

Its optical interface consists of two independent 400G DR4 paths. Each path carries four 100G PAM4 optical lanes through an MPO-12/APC connector. Together, the two interfaces provide an aggregate optical capacity of 800Gb/s over OS2 single-mode fiber.

The module supports links up to 500 meters when used with the correct single-mode cabling, host-side FEC and compatible OSFP equipment. Before ordering, GK Fiber Optic can verify the host platform, OSFP housing type, port configuration and required compatibility coding.

800G OSFP 2×DR4 Optical Transceiver

An 800G optical module is a high-speed optical communication module supporting a data transmission rate of 800 gigabits per second (800Gbps). As an upgrade to the 400G optical module, it primarily performs the conversion between electrical and optical signals, serving as a core "bridge" connecting AI computing clusters, data centers, and high-speed networks.

Product Highlights

  • 800Gb/s aggregate optical transmission capacity

  • Hot-pluggable OSFP form factor

  • Eight 106.25Gb/s PAM4 electrical lanes

  • Two independent 400G DR4 optical interfaces

  • Dual MPO-12/APC optical connectors

  • Up to 500m over OS2 single-mode fiber

  • 1310nm parallel single-mode optical transmission

  • Digital diagnostic monitoring through the management interface

  • Commercial operating case temperature from 0°C to 70°C

  • Maximum power consumption up to 16W

  • Compatible coding and OEM labeling available

Is This the Correct 800G Module for Your Link?

This module is suitable when your network requires all of the following:

  • An 800G OSFP host port

  • A 500m or shorter single-mode fiber link

  • Two MPO-12/APC optical connections

  • An eight-lane 100G PAM4 host electrical interface

  • 800G operation or supported 2×400G port configuration

Do not select this product only by data rate. OSFP modules may use different heatsink designs, connector arrangements, optical standards and host configurations. A single-MPO DR8 module, dual-MPO 2×DR4 module and 800G FR4 module are not automatically interchangeable.

Technical Specifications

Product modelGK-OSFP-800G-2DR4
Product type800G OSFP 2×DR4 optical transceiver
Aggregate data rate800Gb/s
Host electrical interface8 × 106.25Gb/s PAM4
Optical architecture2 × 400G DR4
Optical lane rate8 × 106.25Gb/s PAM4
Form factorOSFP
Optical wavelength1310nm band
Maximum link distanceUp to 500m
Fiber typeOS2 single-mode fiber
Optical connectorDual MPO-12/APC
Modulation formatPAM4
Forward error correctionHost-side KP4 FEC required
Power supply3.3V
Maximum power consumption16W
Operating case temperature0°C to 70°C
Digital diagnosticsSupported
Management interfaceCMIS compatible
InstallationHot-pluggable
Form-factor complianceOSFP MSA

Specifications may vary according to the required host compatibility, thermal design and approved product configuration. Final parameters should be confirmed on the quotation and product datasheet.

How the 800G 2×DR4 Interface Works

On the transmit side, the module converts eight high-speed PAM4 electrical input lanes into eight parallel optical signals. These optical lanes are divided into two four-lane groups, with each group presented through one MPO-12/APC interface.

On the receive side, the module converts the eight incoming optical lanes back into electrical PAM4 signals for the host system. The two optical groups can operate as one aggregate 800G connection or in supported 2×400G configurations, depending on the capabilities and configuration of the host platform.

Typical Applications

  • 800G Ethernet data center interconnects

  • AI training and inference clusters

  • GPU and accelerator network fabrics

  • Leaf-to-spine and spine-to-super-spine connections

  • High-performance computing networks

  • Cloud data center switching infrastructure

  • Supported 800G and 2×400G switch connections

Compatibility Information Required Before Ordering

The OSFP form factor alone does not guarantee compatibility. Please provide the following information so that the module and link configuration can be checked before shipment:

  1. Switch, router or network adapter manufacturer

  2. Exact equipment model and operating system version

  3. Original transceiver part number, if available

  4. Required port mode: 800G or 2×400G

  5. OSFP housing type: finned-top or flat-top/RHS

  6. Fiber length and estimated channel loss

  7. MPO connector type, polarity and patch-cord configuration

  8. Required compatibility coding or custom EEPROM information

Breakout operation depends on the host ASIC, firmware, port configuration and cabling architecture. Please confirm these conditions before using the module for a 2×400G link.

Testing and Quality Control

Product validation can be performed according to the approved configuration and customer requirements. Typical release checks include:

  • Transmitter optical power and extinction-ratio verification

  • Receiver sensitivity and link-performance testing

  • Bit-error-rate testing under the specified FEC configuration

  • Digital diagnostic monitoring verification

  • CMIS and EEPROM information checks

  • Host compatibility and module-identification testing

  • MPO connector end-face inspection

  • Operating-temperature testing according to the approved test plan

  • Serial-number and production-batch traceability

OEM and Compatibility Services

GK Fiber Optic supplies 800G optical modules for network integrators, equipment vendors, data center operators and optical networking distributors. Available services include:

  • Compatibility coding for supported equipment platforms

  • Customer-specific product labels and part numbers

  • Sample supply for platform and link validation

  • Customized EEPROM information

  • Neutral or customized packaging

  • Batch testing records and serial-number traceability

  • Volume-order and scheduled-delivery support

800G OSFP 2×DR4 Frequently Asked Questions

What does 2×DR4 mean?

The module contains two groups of four parallel optical lanes. Each group provides a 400G DR4 optical interface, giving the module an aggregate capacity of 800Gb/s.

What fiber is required for this 800G transceiver?

The 500m version is designed for OS2 single-mode fiber. It should not be specified as a multimode optical module.

Does the module use one or two MPO connectors?

This 2×DR4 configuration uses two MPO-12/APC optical connectors. Confirm the connector polish, key orientation and cable polarity before installation.

Can it be used as two separate 400G connections?

It may support 2×400G operation when the host port, ASIC, firmware and breakout configuration provide this capability. The module alone cannot enable an unsupported breakout mode.

Is 2×DR4 the same as an MPO-16 DR8 module?

No. Both designs may carry eight parallel optical lanes, but their connector arrangement and cabling requirements can be different. A dual MPO-12 module should not be replaced with an MPO-16 module without checking the complete optical path.

Does it support digital diagnostic monitoring?

Yes. Operating information such as module temperature, supply voltage and optical channel conditions can be accessed through the supported management interface. The exact values available depend on the CMIS implementation.

Will it work in any OSFP switch?

Not necessarily. Mechanical design, host coding, firmware, power limits, thermal requirements and port configuration must all be checked. Providing the exact switch model is the fastest way to confirm compatibility.

What information is needed for a quotation?

Please provide the equipment manufacturer and model, required quantity, port mode, fiber distance, OSFP housing type, destination country and any compatibility or labeling requirements.

Request an 800G OSFP 2×DR4 Quote

Send us your switch model, required quantity and link configuration. Our team will check the OSFP housing, compatibility coding, optical interface and cabling requirements before preparing the quotation.

Manufacturer Support

Confirm compatibility before placing your order.

Send the equipment model, required configuration, quantity and delivery destination. We can review compatibility, sample requirements, OEM labeling and volume supply.

GK Fiberoptic WeChat QR code

Scan to add WeChat